Denkerzelle im Raum-in-Raum Prinzip als autarkes Raumelement

Room in room Electrification

The think tank vetroCUBE is delivered ready to use

The room in room system vetroCUBE is delivered with ready to use 230 V electrification. All electrotechnical elements installed in the thinker cell are internally pre-wired. For 230 V electrification, all functions are combined in a control box on the ceiling element. Here we find the interface, a socket Wieland GST18i3FS2RV, for the mains connection. Our fitters connect here temporarily and test all functions. The formal commissioning must be carried out by a local electrician. For data electrification, the responsible electrician hands over the appropriate cables to us so that we can pull them to the prepared slots during installation in the solid walls of the room in room system.

Think tank in space in space Construction method with electrification

  • ready-to-use electrification
  • Feeding of connection cable from floor or ceiling possible
  • internally pre-wired
  • Control box with defined interface for the mains connection on the ceiling element
  • Plug-in fields or interfaces for power and data on request (Schuko, RJ 45, USB, HDMI etc.)
  • Intelligent control of light and ventilation via presence detector and touch screen
  • Optional system base for cable routing
Picture of a room in room unit diagonally from above with control box on the ceiling element.
Room in room unit with control box on the ceiling element. This is where all functions converge and where the interface for the mains connection is found.

Connection to the building structure:

As self-sufficient as the room in room system may be, it has to be connected to the building structure in terms of electrical engineering and data technology. For the 230 V connection, the defined interface can be found on the ceiling element of the vetroCUBE. See also first paragraph. If the cables come from the ceiling, the small switch box, the control box, is directly accessible. If the cables come from the floor, they must first be led upwards through a solid wall element onto the ceiling element. For this purpose, appropriate cable lengths must be provided by the customer so that our fitters can pull them in directly. The same applies to data cables. We also install these if provided by the customer.

Room in room Connection via ceiling
Connection and data cables fed via the ceiling of the building
Room in room Connection via raised floor
Connection and data cables fed via the raised floor

The room-in-room system can be adapted to your individual electrical requirements.

The standard electrical equipment of the thinker cell according to the room-in-room design consists of a ventilation unit, an LED linear luminaire, a presence detector, a radio button for switching and dimming the luminaire and a flush-mounted socket unit with three 230 V Schuko sockets and two RJ 45 patch-to-patch panels for data lines.

Room in room fully electrified
Room in room with screen and electrification

Intelligent control of room-in-room systems

Light and ventilation are controlled in the standardised room-in-room electrification via the presence detector recessed in the ceiling. When entering the room in room system, light and ventilation are switched on. The user can adjust light and ventilation via a TFT display (touch screen). The light can be dimmed according to requirements. The ventilation can be briefly set to "air shower" for approx. 30 seconds, thus doubling the volume flow. After this time has elapsed, the ventilation drops back to the preset value so that the fan cannot be heard. If the user leaves the vetroCUBE, the presence detector switches off the light promptly and allows the ventilation to continue for approx. 10 minutes. The fan then falls into a "freshness mode". Between 6 o'clock in the morning and 22:00 o'clock in the evening, it delivers a minimum volume flow of approx. 50 m³/h, so that the vetroCUBE is always "ventilated". All parameters can be individualised by Facility Management via a stored PIN.

Solid wall think tank with slots
The think tank can be individually electrified as desired. Integrated modules are wired internally.
Screen holder and electrification on solid wall
TV bracket and extension electrification for Denkerzelle
Control panel on frame for the vetroCUBE system
In addition to the presence control of the light, the user can exert influence via the control panel. The light here can be switched and dimmed.

space efficiency

The think tank uses the middle zone in the office. The facade remains free for workplaces: The architecture of the office can thus be optimally used.

room acoustics

vetroCUBE offers soundproof retreat rooms in open space. Employees find retreat rooms for working in groups.

Plug and Play

vetroCUBE is supplied with ready to use 230 V electrification. The "plug and play" principle applies so that commissioning is simple.

ventilation

The system ventilation of the Think Tank vetroCUBE ensures the supply of fresh air. An acoustically optimised fan box is located on the ceiling.

cooling

The vetroCUBE system offers the option of room cooling. Long use and dense occupancy can lead to heating of the cube.

light

The Think Tank vetroCUBE offers a flexible LED lighting concept. It can be adapted to different uses and different sizes.

construction

The room in room system vetroCUBE is a modular system. The cubes can be individually adapted to sizes and design requirements.

fire protection

The room in room system can easily be equipped with the necessary fire protection technology, smoke detectors, sprinklers and / or loudspeakers.

work settings

The room-in-room system can be designed specifically for work settings in terms of size, equipment and decoration.

Solutions

The think tank can be optimized for many applications. Here are a few examples. Tell us your wishes. We build your vetroCUBE.